Patch Manager is an intuitive patch management software which extends the capabilities of WSUS and SCCM to not only patch Windows® servers and workstations, and Microsoft® applications, but also other 3rd-party applications which are commonly exploited by hackers. Learn more about our patch management solution.

 

Home > Success Center > Network Performance Monitor (NPM) > Alert shows no drop-down menu

Alert shows no drop-down menu

Created by Norbert Skurzewski, last modified by MindTouch on Jun 23, 2016

Views: 44 Votes: 1 Revisions: 3

Overview

This article addresses an issue with alerts not showing the drop-down menu when editing the old alerts or creating a new alert such as, Node Status is equal to... no drop-down menu.

Environment

NPM 11.5.3 and earlier versions

Cause 

There seems to be an issue with the alerting engine and it shows ERROR NewAlertingService - 
System.InvalidOperationException: Sequence contains no elements in the logs
.

To check this error, go to C:\ProgramData\SolarWinds\Logs\Orion and open Alerting.Service.V2 log.

Resolution

  1. Run the Configuration Wizard as an administrator.
  2. Select all 3 options (Database, Services, Website).
  3. Allow the Configuration Wizard to finish, do not skip website optimization.
  4. Open the Web Console. If there is an error (as the plugins have not fully started yet), try again after a few minutes.

 