Home > Success Center > Network Performance Monitor (NPM) > Alert does not trigger for a particular node

Alert does not trigger for a particular node

Updated June 19, 2017

Overview

This article describes an issue where an alert does not trigger on a particular node after installing NPM 12. The same alert works fine for other nodes.

Environment

NPM 12

Cause 

This issue occurs when the dual and primary NIC polled IP addresses are set as DHCP in Orion.

Resolution

Edit the node and disable the DHCP enabled option in Orion.

 