The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Configuration Manager (NCM) > Upgrade error: Violation of PRIMARY KEY constraint 'PK_NCM_RouteTable'. Cannot insert duplicate key in object 'dbo.NCM_RouteTable'. The statement has been terminated.

Upgrade error: Violation of PRIMARY KEY constraint 'PK_NCM_RouteTable'. Cannot insert duplicate key in object 'dbo.NCM_RouteTable'. The statement has been terminated.

Created by Mariusz Handke, last modified by Kevin.Swinson on Nov 09, 2017

Views: 227 Votes: 1 Revisions: 8

Updated April 9th, 2017

Overview

The following error appears when upgrading or migrating to NCM version 7.3 or later:

Violation of PRIMARY KEY constraint 'PK_NCM_RouteTable'. Cannot insert duplicate key in object 'dbo.NCM_RouteTable'. The statement has been terminated.

Environment

NCM 7.3 or later

Cause

There were changes in the NCM database schema in v7.3.

Resolution

As a workaround, skip the migration of the inventory data.

Warning: These steps will modify the Windows Registry. Make sure to backup your registry prior to making any changes.

  1. Open the command prompt on the NCM host.
  2. Execute one of the following commands:
  •  For 32 bit system:
reg add "HKLM\Software\SolarWinds.Net\Configuration Manager\Settings" /v DataToMigrate /t REG_SZ /d 3;1
  • For 64 bits system: 
reg add "HKLM\Software\Wow6432Node\SolarWinds.Net\Configuration Manager\Settings" /v DataToMigrate /t REG_SZ /d 3;1
  1. When prompted, type Y to overwrite the existing key.
  2. Restart the Orion Module Engine by going to Windows Services to initiate migration process again.

 

 