Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Configuration Manager (NCM) > Script used to configure a Banner on a Cisco device takes a long time or times out

Script used to configure a Banner on a Cisco device takes a long time or times out

Table of contents
Created by Bill Corgey, last modified by MindTouch on Jun 23, 2016

Views: 182 Votes: 2 Revisions: 3

Overview

The Execute Command Script used to configure a banner on a Cisco device takes a long time.

Environment

  • NCM 6.1 or later

Steps

When using NCM to add or modify a banner, disable prompt detection as this is only one command and the NCM logic will check often for a prompt, causing excessive time for the script to complete.

To work around this, add macros in the script to tell NCM not to check for a prompt, and then turn the prompt detection back on once the banner command is complete.

 

${DisablePromptDetection} will turn this off and ${EnablePromptDetection} will re-enable it.

 

In the command, do the following:

 

conf t

${DisablePromptDetection} 

banner motd ^C

*******

Banner Text here

*******

end

${EnablePromptDetection}

 

This will result in a speedier process.

 

 

 

 