Submit a ticketCall us

Announcing NCM 7.7
With NCM 7.7, you can examine the rules that make up an access control list for a Cisco ASA device. Then you can apply filters to display only rules that meet the specified criteria, order the rules by line number or by the hit count, and much more.
See new features and improvements.

Home > Success Center > Network Configuration Manager (NCM) > Resource Key 'NCMXMLDATA_VM_01' was not found in Resource File 'NCM.Strings'

Resource Key 'NCMXMLDATA_VM_01' was not found in Resource File 'NCM.Strings'

Created by Marjune Obana, last modified by Flavio Porfirio Correia on Nov 11, 2016

Views: 105 Votes: 1 Revisions: 8

Overview

The following errors appear in the logs when loading the Orion Web Console after upgrading from NCM 7.3 to NCM 7.4.1:

 

OrionWeb.log shows the following error:

2016-04-05 12:28:55,211 [31] ERROR SolarWinds.Orion.Core.Common.ModuleCollectionLoader - Error while loading Module Collection data.
SolarWinds.Internationalization.Exceptions.TokenSubstException: Resource Key 'NCMXMLDATA_VM_01' was not found in Resource File 'NCM.Strings'
   at SolarWinds.Internationalization.Tokens.TokenSubstitutionBase.WriteToken(Dictionary`2 values, IResourceStringRegistrar resMgr, TextWriter textOut)
   at SolarWinds.Internationalization.Tokens.TokenSubstitutionBase.Parse(IResourceStringRegistrar resMgr, TokenSubstitutionSequence sequence, TextReader textIn, TextWriter textOut)

 

Preinstaller.log shows the following error:

*** Assembly SolarWinds.Orion.Common, Version=2.0.0.0, Culture=neutral, PublicKeyToken=316e86daa515e407, .NET version v4.0.30319 ***
2016-04-05 10:58:52,561 [1] ERROR SolarWinds.Orion.Common.OrionConfiguration - Settings file 'SWNetPerfMon.DB' N/A - System.AggregateException: One or more errors occurred.
2016-04-05 10:58:52,561 [1] ERROR SolarWinds.Orion.Common.ConnectionStringProvider - File doesn't exists 
2016-04-05 10:58:52,561 [1] ERROR SolarWinds.Orion.Common.ConnectionStringProvider - ConnectionString wasn't found in 
2016-04-05 10:58:52,576 [1] ERROR SolarWinds.Orion.Common.OrionConfiguration - Settings file 'SWNetPerfMon.DB' N/A - System.AggregateException: One or more errors occurred.

Environment

NCM 7.4 and later

Cause 

This occurs when SolarWinds Orion NCM-NPM Integration package did not upgrade to 7.4.

Resolution

  1. Uninstall SolarWinds Orion NCM-NPM Integration v7.3.
    FYI: In case the package is already upgraded (7.4), just repair the NCM-NPM integration application thourgh the control panel.
  2. Run installation package for SolarWinds Orion Network Configuration Manager v7.4.x.

 

Last modified
07:52, 11 Nov 2016

Tags

Classifications

Public