Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Network Configuration Manager (NCM) > Overall Running vs. StartUp Config Conflicts Chart shows Unknown

Overall Running vs. StartUp Config Conflicts Chart shows Unknown

Created by Marjune Obana, last modified by MindTouch on Jun 23, 2016

Views: 26 Votes: 3 Revisions: 8

Overview

The Overall Running vs. StartUp Config Conflicts Chart in NCM shows Unknown.

 

 

Environment

All NCM versions

Cause

#1 There is no config is been downloaded from the devices

#2 There is no  baseline config set for the devices to be compared  

Resolution

You must need to download at least one Start & Running config from the devices & set one configuration as baseline only then  the correct results within this  pie chart will be compared against the baseline . 

 

Step # 1 

  1. On the Web Console, go to Configs > Jobs.
  2. Select Nightly Config Backup and click Edit.
  3. On the Nightly Config Backup edit page, click Next to go to the Add Job Specific Details tab.
  4. Verify that the following are selected:
    • Running
    • Startup
  5. Click Next and then click Finish.
  6. Go back to Configs > Jobs.
  7. Select Nightly Config Backup and click Start Job. 

 

Step #2 

Set basline configuration for your network through NCM Job  

  1. On the Web Console, go to Configs > Jobs. > Create New Job > "Baseline" > Next >  Select "Baseline Entire Network" > Complete the Job 

         

Once Done . Leave the system UP and running for Next hour 

The chart should now display the correct percentages.

Last modified
21:29, 22 Jun 2016

Tags

Classifications

Public