Change management in IT is critical. But, even with a good change management process, changes are too often not correctly tracked, if at all. The configuration of your servers and applications is a key factor in their performance, availability, and security. Many incidents can be tracked back to an authorized (and sometimes unauthorized) configuration change, whether to a system file, configuration file, or Windows® Registry entry. Join SolarWinds VP of product management Brandon Shopp to discover how the new SolarWinds® Server Configuration Monitor is designed to help you.

Register now.

Home > Success Center > Network Configuration Manager (NCM) > NCM - Knowledgebase Articles > There was an error retrieving data from SolarWinds Information Service Invoke failed

There was an error retrieving data from SolarWinds Information Service Invoke failed

Created by Michael Perez, last modified by MindTouch on Jun 23, 2016

Views: 2,349 Votes: 0 Revisions: 4

Overview

This articles describes the steps to resolve an issue where some views that contain NCM resources fail to load.  The Web Console displays the following error message:

 

There was an error retrieving data from SolarWinds Information Service
Invoke failed, check fault information.

 

In Information Service log, the following message is seen:

 

ERROR SolarWinds.InformationService.Core.InformationService - (null) Exception caught in method Invoke
System.IO.FileNotFoundException: Could not load file or assembly 'SolarWinds.NCM.Common, Version=7.4.1.53

Environment

All NCM versions

Cause 

Unknown

Resolution

  1. Open Programs and Features.
  2. Right-click the SolarWinds Network Configuration Manager under Uninstall or change a program.
  3. Click Repair.
  4. Run the Configuration Wizard ensuring that Database, Website, and Services are selected.  