Submit a ticketCall us

WebinarVisual Monitoring Tactics: Getting More Log Search Value from SolarWinds Log & Event Manager with nDepth Webcast

Do things seem to make more sense when they are visualized? Are you an IT professional or security expert with a wish for more cybersecurity tools that provide an intuitive visual experience? Join Alexis Horn and Jamie Hynds from SolarWinds as they demonstrate how the nDepth feature in LEM can help make visualizing log search results a reality.

Register now.

Home > Success Center > Network Configuration Manager (NCM) > NCM - Knowledgebase Articles > Server Error in '/' Application - The resources cannot be found. Requested URL: /Orion/NCM/Resources/Jobs/JobsList.aspx

Server Error in '/' Application - The resources cannot be found. Requested URL: /Orion/NCM/Resources/Jobs/JobsList.aspx

Updated March 5th, 2017

Overview

When accessing NCM 32bit Application, clicking on Scheduled Job will result to opening the console but with an error:

Server Error in '/' Application.

The resource cannot be found.

Description: HTTP 404. The resource you are looking for (or one of its dependencies) could have been removed, had its name changes, or is temporarily unavailable. Please review the following URL and make sure that it is spelled correctly.

Requested URL: /Orion/NCMResource/Jobs/JobsList.aspx

 

Environment

NCM 7.2.2

Cause 

The Website table for NCM should only have the correct row with the same ServerName and IPAddress of the server. This issue happens after migrating NCM to a different server.

Resolution

  1. Open Database Manager > NCM Database > Website table.
  2. Delete unwanted rows by clicking Enable table editing.
 

 

Last modified

Tags

Classifications

Public