Submit a ticketCall us

AnnouncementsChange Is Inevitable

Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Network Configuration Manager (NCM) > NCM - Knowledgebase Articles > Server Error in '/' Application - The resources cannot be found. Requested URL: /Orion/NCM/Resources/Jobs/JobsList.aspx

Server Error in '/' Application - The resources cannot be found. Requested URL: /Orion/NCM/Resources/Jobs/JobsList.aspx

Updated March 5th, 2017

Overview

When accessing NCM 32bit Application, clicking on Scheduled Job will result to opening the console but with an error:

Server Error in '/' Application.

The resource cannot be found.

Description: HTTP 404. The resource you are looking for (or one of its dependencies) could have been removed, had its name changes, or is temporarily unavailable. Please review the following URL and make sure that it is spelled correctly.

Requested URL: /Orion/NCMResource/Jobs/JobsList.aspx

 

Environment

NCM 7.2.2

Cause 

The Website table for NCM should only have the correct row with the same ServerName and IPAddress of the server. This issue happens after migrating NCM to a different server.

Resolution

  1. Open Database Manager > NCM Database > Website table.
  2. Delete unwanted rows by clicking Enable table editing.
 

 

Last modified

Tags

Classifications

Public