Are you ready for your next upgrade? To help you plan smoothly, join this webcast to learn more about, SolarWinds® Orion® Installer, SolarWinds Upgrade Advisor, Upgrades Guides, Training Videos, and other resources available. We’ll share key upgrade planning considerations, lessons learned from customers with practical advice from SolarWinds Product Experts. We’ll also give practical tips to identify the estimated time needed and resources, how to prepare the business and IT staff for changes, ways to plan for required system changes, and more.

Register now.

Home > Success Center > Network Configuration Manager (NCM) > NCM - Knowledgebase Articles > NCM job hangs in downloading state

NCM job hangs in downloading state

Created by Anthony.Rinaldi_ret, last modified by MindTouch on Jun 23, 2016

Views: 1,930 Votes: 6 Revisions: 12

Overview

An NCM job created to push configs to 500 or more devices hangs in a Downloading state.

Environment

  • NCM 7.4.1 and earlier

Cause

The issue comes from sending the Real Time Notification email.

Resolution

This issue is fixed in upcoming release of NCM. On NCM 7.4.x and earlier you can work around the issue by switching to the old VB6 Real Time Notification engine:

  1. Start the Syslog Viewer in the SolarWinds Orion program folder.
  2. Click View > Alerts/Filter Rules.
  3. Select the NCM rule for real time change notifications, and click Edit.
  4. Click the Alert Actions tab.
  5. Select the Execute SolarWinds.NCM.RTNForwarder.exe action, and click Edit Selected Action.
  6. In the Program to execute field, add the /old switch after the .exe file:

    Current value
    C:\Program Files (x86)\SolarWinds\Orion\SolarWinds.NCM.RTNForwarder.exe ${IP_Address},RealtimeNotification,${DateTime},${Message}

    New value
    C:\Program Files (x86)\SolarWinds\Orion\SolarWinds.NCM.RTNForwarder.exe /old ${IP_Address},RealtimeNotification,${DateTime},${Message}

  7. Click OK, and click OK to close the Edit Syslog Rule window.

 

 

 