Do things seem to make more sense when they are visualized? Are you an IT professional or security expert with a wish for more cybersecurity tools that provide an intuitive visual experience? Join Alexis Horn and Jamie Hynds from SolarWinds as they demonstrate how the nDepth feature in LEM can help make visualizing log search results a reality.

Register now.

Home > Success Center > Network Configuration Manager (NCM) > NCM - Knowledgebase Articles > NCM backups fail on the additional polling engine

NCM backups fail on the additional polling engine

Updated July 14, 2017

Overview

Scheduled backups on devices attached to an additional polling engine fail with the following error:

Unable to connect to polling engine [host name] on the relevant server. Verify that NCM 7.3.2 or later is installed on the server

Environment

All NCM versions

Cause 

The polling engine time is out of sync for more than five minutes with the main polling engine.

The license has not been applied to the additional polling engine or the evaluation license has expired.

Resolution

  1. Verify the time on the main polling engine server.
  2. Adjust the time on the additional polling engine to be the same as the main polling engine.
  3. Restart the Orion services on the additional polling engine using Orion Service Manager.

 