Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Network Configuration Manager (NCM) > Inventory Data Missing for VLANs

Inventory Data Missing for VLANs

Overview

This article provides information on addressing issue with incomplete VLAN information collected from devices in device inventory in NCM 7.0 and later.

Environment

NCM 7.0 and later

Cause

Likely cause is that the VLAN or Extended VLAN information collection is disabled.

Resolution

When VLAN information is incomplete try these steps:

  1. Enable the "Extended VLANs Inventory" option on the Inventory Settings page (Settings > NCM Settings > Node Inventory).
  2. Restart the NCM Win32 application
    Note: In NCM 7.4 and later the Win32 Desktop Application does not exist anymore
  3. Re-run the device inventory.

 

If the VLANS are still not displaying, confirm with an SNMP walk the device is sending the vlan information based on the RFC IF-MIB.

VLAN information currently is collected on Cisco devices using CISCO-VLAN-MEMBERSHIP-MIB and CISCO-VTP-MIB.