Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Network Configuration Manager (NCM) > Install NCM APE (Additional Polling Engine) on a different drive

Install NCM APE (Additional Polling Engine) on a different drive

Table of contents
Created by John Salvani, last modified by MindTouch on Jun 23, 2016

Views: 15 Votes: 2 Revisions: 5

Overview

This article provides brief information on the effects of installing the NCM APE on a different drive letter (not the same as on the main NCM PPE server installation directory). 

Environment

NCM version 7.4.1 or later

Detail

When you install NCM APE on a different drive letter that does not correspond with the drive letter where you install the Main NCM server. This will cause an issue where the Syslog and Trap viewer setting for RTNForwarder.exe will only use one drive letter globally.

 

SolarWinds recommends installing the APE on the same drive letter on the Main NCM server and APE server. However. if you have already installed the APE on a different drive letter and the NCM main server, do the following:

 

Create separate alert action RTNForwarder.exe for each poller and set correct path and create new rule for each drive letter.

 

For example, SyslogRule actions will looks as follow:

 

    1st Action

C:\Program Files (x86)\SolarWinds\Orion\SolarWinds.NCM.RTNForwarder.exe ${IP_Address},RealtimeNotification,${DateTime},${Message}

 

    2nd Action

E:\Program Files (x86)\SolarWinds\Orion\SolarWinds.NCM.RTNForwarder.exe ${IP_Address},RealtimeNotification,${DateTime},${Message}

 

 

 

 

 

Last modified
21:08, 22 Jun 2016

Tags

Classifications

Public