This articles goes over what causes the configuration wizard error and how to remediate it. 

 

Environment

All versions of NCM

 

Cause 

The cause of this error during the installation and configuration wizard is there are no permissions for C:\Windows\Temp folder and the configuration wizard is unable to access the path.

 

Resolution

  1. Navigate to the C:\Windows\Temp and right-click and select Properties.
  2. Go to the Security tab and click on Edit to change the permissions.
  3. Either click on Add and enter Network Services to add or select Network Services if already in placed.
  4. Below you will see the Permissions, select Modify and then click OK.
    1. Note: In addition to this, run the Orion Permission Checker to verify that all the permission for Orion products are in placed.

 

 

 