Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Configuration Manager (NCM) > Configuration Wizard Error - NCM Integration Plugin Component

Configuration Wizard Error - NCM Integration Plugin Component

Created by Andrew Heinzer, last modified by MindTouch on Jun 23, 2016

Views: 55 Votes: 2 Revisions: 6

Overview

The following error appears when running the Orion Configuration Wizard while updating NCM

Exception while configuring plugin Solarwinds NCM Integration Plugin component Orion Database

System.Security.Permissions.RegistryPermission, mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=........

 

Environment

  • NCM 7.4

 

Cause 

There is a permissions failure with one of the prerequisite modules for NCM.

Resolution

  1. Run the Orion Permission Checker tool.  This is located in the Orion install folder located by default in C:\Program Files (x86)\Solarwinds\Orion\OrionPermissionChecker.exe
  2. Repair all listed permissions.
  3. Re-check to confirm there are no failures.
    Note: In cases where failures recur in a short time, set the permissions to those folders manually.
  4. Network Service with full control should be added to the Windows Temp folder as well

 

 