Submit a ticketCall us

Don’t fall victim to a ransomware attack
Backups are helpful, but sometimes that’s not enough to protect your business against ransomware. At our live webcast we will discuss how to protect against ransomware attacks with SolarWinds® Patch Manager and how to leverage log data to detect ransomware. Register now for our live webcast.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Unable to find assembly 'SolarWinds.DPI.BusinessLayer'

Unable to find assembly 'SolarWinds.DPI.BusinessLayer'

Created by Michael Perez, last modified by MindTouch on Jun 23, 2016

Views: 5 Votes: 1 Revisions: 3

Overview

This article describes how to correct an issue adding a Node when NTA is installed.  If you check the BusinessLayerHost.log file you will find the error:

Unable to find assembly 'SolarWinds.DPI.BusinessLayer'

Environment

NTA 4.1.2 and earlier

Cause 

This is caused by installing only 64-bit C++ 2013 runtime (part of NTA installation). If there is an older build of 32-bit C++ 2013 runtime, it was uninstalled for unknown reason.  

Resolution

  1. Download vcredist_x86.exe from the Microsoft website.
  2. Run the installer.  
  3. Restart all Orion services from the Orion Service Manager.  
  4. Test by adding the device again.  
Last modified
21:00, 22 Jun 2016

Tags

Classifications

Public