Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Troubleshoot CBQoS SNMP Walk

Troubleshoot CBQoS SNMP Walk

Table of contents

Updated July 27, 2016

Overview

This article describes how to investigate when CBQos is sending values to NTA.

Environment

All NTA versions

Steps

  1. Find OID .1.3.6.1.2.1.2.2.1.2.[X]. The interface name will appear and [X] is the interface index.
    For example, .1.3.6.1.2.1.2.2.1.2.11 = STRING: "GigabitEthernet0/1.3"
  2. Find OID 1.3.6.1.4.1.9.9.166.1.1.1.1.4.[Y] = [interface index]. 
    Note: [Y] will later be matched with the policy.
    For example, .1.3.6.1.4.1.9.9.166.1.1.1.1.4.176 = INTEGER: 11
    Based on polled SNPM OID by NTA you cal also obtain policy/class names
  3. Find OID 1.3.6.1.4.1.9.9.166.1.15.1.1.17.
    Note: This OID is for drops and if you match it with [Y], you can obtain the values that the device is sending.

    For example:

    .1.3.6.1.4.1.9.9.166.1.15.1.1.17.176.8323105 = COUNTER64: 0
    .1.3.6.1.4.1.9.9.166.1.15.1.1.17.176.15388929 = COUNTER64: 0

 