Submit a ticketCall us

Announcing NPM 12.2
With NPM 12.2 you can monitor your Cisco ASA firewalls, to monitor VPN tunnels for basic visibility and troubleshooting tunnels. NPM 12.2 also uses the SolarWinds Orion Installer so you can easily install and upgrade one or more Orion Platform products simultaneously.
See new features and improvements.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Set a fixed memory limit for the Flow Storage (Fastbit) Database

Set a fixed memory limit for the Flow Storage (Fastbit) Database

Table of contents
Created by Justin Wyllys, last modified by MindTouch on Jun 23, 2016

Views: 87 Votes: 0 Revisions: 5

Overview

This article describes how to adjust the amount of memory that can be allocated to the Flow Storage (Fastbit) Database.

Environment

NTA 4.x (64-bit)

Steps

Warning: SolarWinds strongly recommends that you only edit the ServerConfig.xml file as instructed. Any additional modifications may result in system performance issues or may create an error state.

  1. Open the c:\ProgramData\Solarwinds\NTA\FlowStorage\ServerConfig.xml file in a text editor.
  2. Locate the following line and modify the maximum memory utilization:
<viewBytesMaximum>80%</viewBytesMaximum> 

Notes: 

  • The default maximum memory utilization is set to 80%. It means that at most, 80% of whole system memory will be used by the FSDB.
  • You can specify the value in MB. For example, <viewBytesMaximum>1024</viewBytesMaximum> means 1GB of the limit.
  1. Restart NTA Flow Storage Service for changes to take effect.

 

 

Last modified
20:58, 22 Jun 2016

Tags

Classifications

Public