Submit a ticketCall us
Home > Success Center > Netflow Traffic Analyzer (NTA) > Server error in NTA 3.11: Cannot display router/switch for unmonitored traffic in Top XX Applications

Server error in NTA 3.11: Cannot display router/switch for unmonitored traffic in Top XX Applications

Table of contents
No headers
Created by Interspire Import, last modified by Kevin.Swinson on Nov 09, 2017

Views: 954 Votes: 0 Revisions: 9

Updated on April 28th, 2016

 

Issue

Top XX Applications resource on the NetFlow Applications Summary view does not display routers or switches under unmonitored ports. Trying to display them results in a server error.  You can encounter this error if you log in to your Orion Web Console, select the NETFLOW tab > Apps, click Unmonitored traffic in the Top XX Applications resource to get to the NetFlow Applications Summary View and expand an application in the Top XX Applications resource there.

This issue occurs if you are using NTA 3.11 with NPM 10.5.

Cause

The server error is caused by the integration of NPM 10.5 and NTA 3.11.

Resolution

Upgrade your NPM to version 10.6.

Last modified

Tags

Classifications

Public