Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > SQL macro alert action does not display the full path (FQDN)

SQL macro alert action does not display the full path (FQDN)

Updated April 20, 2017

Overview

The following SQL alert macros do not properly return the full path (FQDN) of the SolarWinds Orion Web Console for the displayed link. It only shows a \\ at the start of the string instead of the hostname of the server:

 

  • ${SQL:SELECT Macro FROM NetFlowAlertMacros WHERE ID='InInterfaceDetailsLink'}
  • ${SQL:SELECT Macro FROM NetFlowAlertMacros WHERE ID='OutInterfaceDetailsLink'}

 

The NTA generated link for each of the actions is similar to the following:

\\Orion\TrafficAnalysis\NetflowInterfaceDetails.aspx%3fViewKey=NetFlow%2520Interface%2520Details%2520for%2520Alerts&NetObject=NI:XXXXX;T:2017-04-11T15:49:18~2017-04-11T15:54:18;FD:

Environment

NTA 4.2.2 and earlier

Cause 

The issue is caused when relative IDs are used in the macro where they should be "absolute" variations.

Resolution

Use the following IDs with the absolute path:

  • InInterfaceDetailsLinkAbsolute
  • OutInterfaceDetailsLinkAbsolute

 

 

 