Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NetFlow Collector Services page shows a blank entry after renaming a server

NetFlow Collector Services page shows a blank entry after renaming a server

Updated March 22, 2017

Overview

After renaming the server host name of the NTA application server, a blank entry shows under NetFlow Collector Services.

nta_collector_page_blank_after_renaming.png

Environment

All NTA versions

Cause 

The server name has two entries because the old entry was not deleted by the configuration wizard.

Resolution

  1. Open Database Manager.
  2. Go to the FlowEngines table.
  3. Click Enable table editing.
  4. Right-click the entry that is not updated based on the FLowCollectorKeepAlive column.
  5. Click Delete the selected row(s).
  6. Click Enable table editing again to save the change.
  7. Refresh the NetFlow Collector Services page.
    The page now shows a single entry for the server.
 

 