Submit a ticketCall us

Announcing NCM 7.7
With NCM 7.7, you can examine the rules that make up an access control list for a Cisco ASA device. Then you can apply filters to display only rules that meet the specified criteria, order the rules by line number or by the hit count, and much more.
See new features and improvements.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NetFlow Collector Services page shows a blank entry after renaming a server

NetFlow Collector Services page shows a blank entry after renaming a server

Updated March 22, 2017

Overview

After renaming the server host name of the NTA application server, a blank entry shows under NetFlow Collector Services.

nta_collector_page_blank_after_renaming.png

Environment

All NTA versions

Cause 

The server name has two entries because the old entry was not deleted by the configuration wizard.

Resolution

  1. Open Database Manager.
  2. Go to the FlowEngines table.
  3. Click Enable table editing.
  4. Right-click the entry that is not updated based on the FLowCollectorKeepAlive column.
  5. Click Delete the selected row(s).
  6. Click Enable table editing again to save the change.
  7. Refresh the NetFlow Collector Services page.
    The page now shows a single entry for the server.
 

 

Last modified
20:31, 23 Mar 2017

Tags

Classifications