Submit a ticketCall us

Training Class Getting Started with SolarWinds Backup - February 28

This course offers customers an introduction to SolarWinds Backup, focusing on configuring the backup technology, taking backups, data restoration and data security. It is a great primer and will get you up to speed quickly on SolarWinds Backup.
Register for class.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NetFlow Collector Services page shows a blank entry after renaming a server

NetFlow Collector Services page shows a blank entry after renaming a server

Updated March 22, 2017

Overview

After renaming the server host name of the NTA application server, a blank entry shows under NetFlow Collector Services.

nta_collector_page_blank_after_renaming.png

Environment

All NTA versions

Cause 

The server name has two entries because the old entry was not deleted by the configuration wizard.

Resolution

  1. Open Database Manager.
  2. Go to the FlowEngines table.
  3. Click Enable table editing.
  4. Right-click the entry that is not updated based on the FLowCollectorKeepAlive column.
  5. Click Delete the selected row(s).
  6. Click Enable table editing again to save the change.
  7. Refresh the NetFlow Collector Services page.
    The page now shows a single entry for the server.
 

 

Last modified

Tags

Classifications

Public