Submit a ticketCall us

AnnouncementsCome see SolarWinds at VMUG Frankfurt

SolarWinds is delighted to attend the upcoming VMUG which will take place at Kap Europa in Frankfurt on June 19th, 2018.

See event details.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA stopped processing flows

NTA stopped processing flows

Created by Brian O'Donovan, last modified by MindTouch on Jun 23, 2016

Views: 903 Votes: 1 Revisions: 4

Overview

NTA has stopped processing flows with the following error:

ERROR:

ERROR FastbitCLR.FastbitTable - Not enough free space on the disk. Free space: 427528192, minimum requested free space: 1073741824.

...

ERROR:

ERROR FastbitCLR.FastbitTable - FastbitTable::AppendDataThread() Exception: Cannot create slot sync.
   at FastbitCLR.FastbitIndex.{ctor}(FastbitIndex* , FastbitColumn* column, VolumeFs volumeFs, SizePredictor predictor)

...

Environment

NTA 4 and later

Cause 

This occurs when the NTA Flow storage DB location is out of space.

Resolution

Move NTA Flow Storage DB to another location.

 

Last modified