Submit a ticketCall us

Training Class Getting Started with SolarWinds Backup - February 28

This course offers customers an introduction to SolarWinds Backup, focusing on configuring the backup technology, taking backups, data restoration and data security. It is a great primer and will get you up to speed quickly on SolarWinds Backup.
Register for class.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA installation website configuration failed: Access to path "C:\Program Files x86\Solarwinds\Orion\HardwareHealth\SolarWinds.VIM.Contract.dll"

NTA installation website configuration failed: Access to path "C:\Program Files x86\Solarwinds\Orion\HardwareHealth\SolarWinds.VIM.Contract.dll"

Updated July 6, 2017

Overview

The following error is displayed when running the configuration wizard after installing NTA:

Website Configuration failed: Access to path "C:\Program Files x86\Solarwinds\Orion\HardwareHealth\SolarWinds.VIM.Contract.dll"

Environment

All NTA versions

Cause 

This can occur due to either a permissions issue or a file lock issue with the DLL file noted in the error.

Resolution

  1. Check permissions using the Orion Permission Checker.
  2. Run the configuration wizard.

If the issue persists, see Error: Some Path is denied.

 

 

 

Last modified

Tags

Classifications

Public