Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA License Issue : Object Reference not set to an Instance of an Object

NTA License Issue : Object Reference not set to an Instance of an Object

Created by Con Finucane, last modified by MindTouch on Jun 23, 2016

Views: 81 Votes: 1 Revisions: 3

Overview

This article addresses the issue where the NTA pages on the Orion Web Console do not display and return the following error:

Unexpected Website Error. Object Reference not set to an Instance of an Object.

The following error is also found in the NTA Business Layer logs (volume\programdata\solarwinds\orion\logs\nta):

License Does Not Match Install Type

Environment

All NTA versions

Resolution

  1. Click Start and Run Regedit.
  2. Create a backup of the registry.
  3. Verify that the value for the following key is FULL:
    Computer/HKEY_LOCAL_MACHINE/SOFTWARE/Wow6432Node/Solarwinds/Orion/Core/Configuration
  4. Restart Orion services.

 

Last modified

Tags

Classifications

Public