Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA Documentation > NTA 4.4 Administrator Guide > NTA Troubleshooting > Troubleshoot Long Flow Errors

Troubleshoot Long Flow Errors

Table of contents
No headers
Created by Lori Krell_ret, last modified by Alexandra.Nerpasova on Oct 21, 2016

Views: 708 Votes: 0 Revisions: 4

Invalid flow errors recorded in the NetFlow Analyzer may result when a flow duration exceeds the cache timeout values. This condition displays the following event in the Traffic Analyzer Events monitor:

NetFlow Receiver Service [Poller] detected long flow with duration 90s on <link>Node</link>

 

To resolve this error, the following lines must appear in the Flow Monitor section of the Configuration file for Flow Records on Cisco devices:

cache timeout inact 10

cache timeout act 5

For additional information, see Configuring Devices for Flow Collection in the online help.

 