You can perform Juniper switch sFlow configuration using the following sample configuration:

sflow {
    polling-interval 30;
    sample-rate 128;
    collector 10.1.2.5 {
    udp-port 2055;
    }
    interfaces ge-0/0/0.0;
    interfaces ge-0/0/1.0;
    interfaces ge-0/0/2.0;
    interfaces ge-0/0/3.0;
    interfaces ge-0/0/4.0;
    interfaces ge-0/0/5.0;
    interfaces ge-0/0/6.0;
    interfaces ge-0/0/7.0;
    interfaces ge-0/0/8.0;
    interfaces ge-0/0/9.0;
    interfaces ge-0/0/10.0;
    interfaces ge-0/0/11.0;
    interfaces ge-0/0/12.0;
    interfaces ge-0/0/13.0;
    interfaces ge-0/0/14.0;
    interfaces ge-0/0/15.0;
    interfaces ge-0/0/16.0;
    interfaces ge-0/0/17.0;
    interfaces ge-0/0/18.0;
    interfaces ge-0/0/19.0;
    interfaces ge-0/0/20.0;
    interfaces ge-0/0/21.0;
    interfaces ge-0/0/22.0;
    interfaces ge-0/0/23.0 {
    	polling-interval 30;
        sample-rate 128;
    }
}

 