To support HP devices, you must configure the device using the following configuration template.

This configuration will not show up in the command line interface. If you reset the switch, you will lose the configuration.

setmib sFlowRcvrAddress.1 -o 1414140a
setmib sFlowRcvrPort.1 -i 2055
setmib sFlowRcvrOwner.1 -D sFlowtool sFlowRcvrTimeout.1 -i 100000000

1414140a is the IP address of your SolarWinds NPM server in hex format.

2055 is the default port NTA listens on. If you changed the default port, replace 2055 with your port.

Add the following lines for each interface. Replace '10' with the interface number.

setmib sFlowFsReceiver.11.1.3.6.1.2.1.2.2.1.1.10.1 -i 1
setmib sFlowFsPacketSamplingRate.11.1.3.6.1.2.1.2.2.1.1.10.1 -i 512
setmib sFlowFsMaximumHeaderSize.11.1.3.6.1.2.1.2.2.1.1.10.1 -i 128
setmib sFlowCpReceiver.11.1.3.6.1.2.1.2.2.1.1.10.1 -i 1
setmib sFlowCpInterval.11.1.3.6.1.2.1.2.2.1.1.10.1 -i 30

 