Brocade (Foundry) sFlow configuration

Table of contents
No headers
Created by Lori Krell_ret, last modified by Alexandra.Nerpasova on Oct 21, 2016

Views: 43 Votes: 0 Revisions: 4

To support Foundry devices, you must configure the device using the following configuration template.

Ensure your Foundry device supports sFlow version 5.

config> int e 1/1 to 4/48
interface> sflow forwarding
config> sflow destination 10.199.1.199 2055
config> sflow sample 128
config> sflow polling-interval 30
config> sflow enable

The sFlow destination value must reflect the IP address of your SolarWinds NPM server. This value also contains the port number (2055) that is required in this step.

 