Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA 4.2.3 Administrator Guide > NTA Troubleshooting > Troubleshoot Long Flow Errors

Troubleshoot Long Flow Errors

Table of contents
No headers
Created by Lori Krell_ret, last modified by Alexandra.Nerpasova on Oct 21, 2016

Views: 76 Votes: 0 Revisions: 4

Invalid flow errors recorded in the NetFlow Analyzer may result when a flow duration exceeds the cache timeout values. This condition displays the following event in the Traffic Analyzer Events monitor:

NetFlow Receiver Service [Poller] detected long flow with duration 90s on <link>Node</link>

 

To resolve this error, the following lines must appear in the Flow Monitor section of the Configuration file for Flow Records on Cisco devices:

cache timeout inact 10

cache timeout act 5

For additional information, see Configuring Devices for Flow Collection in the online help.

 