Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA 4.2.2 is not compatible with NPM 12.2

NTA 4.2.2 is not compatible with NPM 12.2

Updated September 8, 2017

Overview

The production version of NTA 4.2.2 crashes with NPM 12.2 during startup of the NTA service. NTA 4.2.2 is therefore not compatible with the NPM 12.2.

Environment

  • NTA 4.2.2

Detail

The NTA log file NTA.BusinessLayer.log reports the following errors:

ERROR SolarWinds.Orion.NetFlow.Service.Program - NetFlowService will be abnormally terminated - Unhandled exception.

System.IO.FileNotFoundException: Could not load file or assembly 'SolarWinds.Orion.Configuration'

Resolution

To solve this know issue, upgrade NTA from version 4.2.2 to version 4.2.3.

The workaround for NTA version 4.2.2 is to copy the file SolarWinds.Orion.Configuration.dll from the folder C:\Program Files (x86)\SolarWinds\Orion to the folder C:\Program Files (x86)\SolarWinds\Orion\NetFlowTrafficAnalysis.

 

 