In this video broadcast, Head Geek™ Tom LaRock is joined by Karen Lopez, Tim Chapman, and David Klee. They’ve known each other for many years, so this discussion was like four friends getting together to talk data and databases. They discussed diagnostic data collection, common performance root causes, reactive tuning versus proactive, and more. Join us for an engaging discussion on these topics! Plus, Tom LaRock will be available to answer your questions live.

Register now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > Orion NTA 3.8 does not install on Windows Server 2003

Orion NTA 3.8 does not install on Windows Server 2003

Table of contents
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 726 Votes: 0 Revisions: 8

Issue:

NTA 3.8 installer does not load on Windows Server 2003. During attempted installation, a MaintDateCheck.exe error occurs. 

The installation issue is caused by storing the MaintDateCheck.exe file to a directory whose path contains at least one space. For example, the MaintDateCheck.exe file may be residing in: C:\Documents and Settings\All Users\Application Data\SolarWinds\Logs\NTA\Installer\MSIs\.

Solution:

To resolve this issue:

  • Upgrade to NTA 3.9.

    or 
     
  • Complete the following procedure:
     
    1. Check your system to see if the full file path is the same name as part of the subdirectory, which contains space. Possible examples could look like these:
      C:\Documents.txt
      C:\Documents and.exe
      C:\Documents and Settings\All
      C:\Documents and Settings\All Users\Application
    2. If the issue does exist, delete or rename the subdirectory. You can also move the subdirectory to another location.

      Note:  File extensions, such as .exe and .txt, do not matter.