Submit a ticketCall us
Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > Netflow collector service is down after NTA upgrade

Netflow collector service is down after NTA upgrade

Updated Dec 24, 2018

Overview

After a recent upgrade task, you see below message in Orion web console about NetFlow Collector Service is down after the upgrade of NTA.

 

clipboard_e884cc59bb026abd522d594079bde0ede.png

The version of the remote NTA Flow Storage Database server does not match the version of the NTA Main Poller. Please upgrade the remote NTA Flow Storage Database server to the same version.

Environment

  • NTA 4.2.x

Cause

  • NTA module version on FSDB(Flow Storage DB) server does not match with the NTA module on the Main poller

Resolution

  1. Download a separate NTA installer from https://customerportal.solarwinds.com (approx 50 MB file).
  2. Upgrade the Flow Storage Database to the latest version on Main and on Flow storage server.
  3. Run Orion Configuration wizard on Main Poller

To verify which remote server your Flow Storage Database is installed on, see Determine the NTA Flow Storage Database on separate server.

 

 

Last modified

Tags

Classifications

Public