Overview

This article will show how to resolve issues when the following error appears when reinstalling the NTA Flow Storage database (FSDB) and upgrading it to a higher version:

The older version of SolarWinds Orion NetFlow Traffic Analyzer 4.1 cannot be removed. Contact your technical support group.

Environment

  • NTA 4.2.1

Steps

  1. Remove all NTA files located in the folder: C:\ProgramData\SolarWinds\Installers
  2. Check for other files that need to be removed in the folder: C:\ProgramData\Solarwinds\Logs\NTA\Installer\MSIs
  3. Verify that NTA has upgraded to the correct version by going to Control panel > Programs and features, and locating SolarWinds Orion NetFlow Traffic Analyzer.

 

 