Submit a ticketCall us

AnnouncementsFace your biggest database issues head-on

Our new eCourse helps you navigate SQL Server performance blocks by teaching you how to recognize and deal with the three DBA Disruptors: Performance Hog, Blame Shifter, and Query Blocker. Register today to learn how to defend your environment and fend off menacing disruptions.

Register for your free eCourse.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > NTA 4.0 upgrade failure: "Flow Storage is Not Installed"

NTA 4.0 upgrade failure: "Flow Storage is Not Installed"

Table of contents
No headers
Created by Interspire Import, last modified by Caroline Juszczak on Oct 11, 2017

Views: 1,065 Votes: 0 Revisions: 14

Issue:

Unable to upgrade to NTA 4.0 and could not connect to the remote Flow Storage Server with the following error: “Flow storage is not installed”

 

Cause:

The SolarWinds server and the Flow Storage database server communicate over port 17777 and authenticate using a self-signed certificate that is imported from the database while running the Configuration Wizard. The self-signed certificate may have become corrupted.

 

Resolution:

  1. Uninstall the existing version of Netflow Traffic Analyzer.
  2. Stop all SolarWinds Services - Starting or Stopping Orion Services.
  3. Delete the "SolarWinds-Orion" certificate (using Certificate Manager in System folder: C:\Windows\System32\) - See Microsoft Knowledge Base
  4. Run the Configuration Wizard to re-import the certificate into the Primary NPM server (Start > All Programs > SolarWinds Orion > Configuration and Auto-Discovery > Configuration Wizard)
  5. Install NTA 4.0.
  6. Run the Configuration Wizard and connect to the Flow Storage server and complete the installation.

 

Last modified