2018 is the seventh year for THWACKcamp™, and once again we’ll be live October 17 – 18 with packed session tracks covering everything from network monitoring and management, to change control, application management, storage, cloud and DevOps, security, automation, virtualization, mapping, logging, and more.

Register for online sessions.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > Flows from Juniper Devices Not Being Processed

Flows from Juniper Devices Not Being Processed

Table of contents
No headers
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 1,265 Votes: 0 Revisions: 8

Explanation:

To configure Juniper devices you may need to add all subinterfaces (for example, ge-1/0/0.0) as well as interfaces to your device configuration.

Note: The following configuration example for a Juniper 4200 is in no way recommended for you to adopt without change for your own Juniper devices.

*** Juniper switch sflow config (Juniper 4200):

 

set protocols sflow agent-id 10.10.10.10

set protocols sflow polling-interval 60

set protocols sflow sample-rate ingress 100

set protocols sflow sample-rate egress 100

set protocols sflow source-ip 10.10.10.10

set protocols sflow collector 123.123.123.123

set protocols sflow interfaces ge-1/0/0.0