Submit a ticketCall us

AnnouncementsFace your biggest database issues head-on

Our new eCourse helps you navigate SQL Server performance blocks by teaching you how to recognize and deal with the three DBA Disruptors: Performance Hog, Blame Shifter, and Query Blocker. Register today to learn how to defend your environment and fend off menacing disruptions.

Register for your free eCourse.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > Configuration Wizard or Repair fails with general 500 internal server error after an NTA upgrade

Configuration Wizard or Repair fails with general 500 internal server error after an NTA upgrade

Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 978 Votes: 0 Revisions: 18

Overview

Web Console is down as the Configuration Wizard or repair fails with general 500 internal server error after upgrading NTA.

Environment

  • NTA 3.9 to 3.10

Cause

This error would occur if there are outdated Netflow dlls on the server.

Resolution

Perform the following steps to fix the issue:
  1. Using command prompt browse to C:\Program Files (x86)\SolarWinds\Orion\Modules\NTA.xml (path may slightly vary depending on the Windows version)
  2. Delete 'NTA.xml' and run a repair on the SolarWinds NTA installation by running the Configuration Wizard - Running Configuration Wizard
  3. A new 'NTA.xml' file will be created as the Configuration Wizard completes successfully
  4. Check if the Web Console is up and running now

 

Last modified

Tags

Classifications

Public
/*]]>*/