Change management in IT is critical. But, even with a good change management process, changes are too often not correctly tracked, if at all. The configuration of your servers and applications is a key factor in their performance, availability, and security. Many incidents can be tracked back to an authorized (and sometimes unauthorized) configuration change, whether to a system file, configuration file, or Windows® Registry entry. Join SolarWinds VP of product management Brandon Shopp to discover how the new SolarWinds® Server Configuration Monitor is designed to help you.

Register now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > NTA - Knowledgebase Articles > ERROR SolarWinds.Netflow.FastBit.Server.Api.NTAFastBitServerService - Error while executing system command

ERROR SolarWinds.Netflow.FastBit.Server.Api.NTAFastBitServerService - Error while executing system command

Created by Malik Haider, last modified by MindTouch on Jun 23, 2016

Views: 1,230 Votes: 0 Revisions: 14

Overview

 

You have received following error when starting NTA service . 

 

The NTA Service restarts with the ASP.Net error message:

 

2015-10-14 09:40:38,752 [73] ERROR SolarWinds.Netflow.FastBit.Server.Api.NTAFastBitServerService - Error while executing system command: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.OutOfMemoryException: Exception of type 'System.OutOfMemoryException' was thrown.

Environment

NTA 4.0.x and later

Cause 

Running the Flow Storage and the Orion database on the same server causes low memory for the Flow Storage Service.

ASP.png

 

Resolution

Migrate Flow Storage and SQL to another dedicated system. For more details, refer to Moving the NTA Flow Storage Database.

 

 