Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Flows from Juniper Devices Not Being Processed

Flows from Juniper Devices Not Being Processed

Table of contents
No headers
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 201 Votes: 0 Revisions: 8

Explanation:

To configure Juniper devices you may need to add all subinterfaces (for example, ge-1/0/0.0) as well as interfaces to your device configuration.

Note: The following configuration example for a Juniper 4200 is in no way recommended for you to adopt without change for your own Juniper devices.

*** Juniper switch sflow config (Juniper 4200):

 

set protocols sflow agent-id 10.10.10.10

set protocols sflow polling-interval 60

set protocols sflow sample-rate ingress 100

set protocols sflow sample-rate egress 100

set protocols sflow source-ip 10.10.10.10

set protocols sflow collector 123.123.123.123

set protocols sflow interfaces ge-1/0/0.0