Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Flapping connection to NTA Flow Storage Database

Flapping connection to NTA Flow Storage Database

Updated October 16, 2017

Overview

The Netflow Collector Service and connection to the NTA Flow Storage Database is flapping, losing and restoring connection repeatedly.

 

NTA Events:

 8/14/2017 1:13 PM   Connection to NTA Flow Storage Database has been lost. NTA cannot save any flows now. 
 8/14/2017 1:14 PM   Connection to NTA Flow Storage Database has been restored. 

 

NTA.BusinessLayer.log

 2017-08-14 13:27:31,190 [95] ERROR SolarWinds.Orion.NetFlow.Service.Program - NetFlowService Disk free space information: Temp - [C:] - 32960266240 bytes free, DB - [C:] - 32960266240 bytes free
2017-08-14 13:27:31,190 [95] ERROR SolarWinds.Orion.Common.SWEventLogging - Unhandled exception - Disk free space information [Temp - [C:] - 32960266240 bytes free, DB - [C:] - 32960266240 bytes free] : The number of WaitHandles must be less than or equal to 64.

 

Environment

  • NTA 4.x

 

Cause 

NTA collector is configured with more than 64 collection ports. The limit of collection ports per collector is 64.

 

Resolution

Edit collection ports and limit it to 64 only.

 

 

Last modified

Tags

Classifications

Public