Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Error while executing script - Difference of two datetime columns caused overflow at runtime

Error while executing script - Difference of two datetime columns caused overflow at runtime

Created by Norsolihati Selamat, last modified by Steven Bansil_ret on Jul 11, 2016

Views: 11 Votes: 0 Revisions: 5

Overview

This article describes the issue when upgrading to NTA 3.9 fails with the following error on the Configuration Wizard:

Error while executing script - Difference of two datetime columns caused overflow at runtime.

Environment

  • NTA 3.9

Resolution

  1. Run the following SQL queries against the Orion database:
    DELETE cbQoSStats
    WHERE YEAR(EndDate) > 9000
     
    UPDATE STATISTICS dbo.cbQoSStats
  2. Re-run the Orion Configuration Wizard.
     

Not: MMake sure a good database backup has already been done before making direct changes to the database.

 

 