The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Error while executing script - 'PK_NetFlowAppsPendingUpdates' is not a constraint

Error while executing script - 'PK_NetFlowAppsPendingUpdates' is not a constraint

Created by Michael Perez, last modified by MindTouch on Jun 23, 2016

Views: 4 Votes: 1 Revisions: 5

Overview

This article describes how to resolve an error that can be encountered during an NTA upgrade.  After installing NTA, the configuration wizard may fail with the error below:  

2016-03-22 11:18:15,757 [17] ERROR DBConfigProcessor - Error while executing script - 'PK_NetFlowAppsPendingUpdates' is not a constraint.
Could not drop constraint. See previous errors..

Environment

NTA 4.1.2 and earlier

Cause 

Unfortunately, the cause of this issue is currently unknown.

Resolution

Note: It is required to have a backup of the Microsoft SQL database before completing any upgrades to Orion (See: https://support.solarwinds.com/Succe...pgrading_Orion)  

 

  1. Drop the table NetFlowFastBitUpdatesApps from the Orion database.
  2. Run the Configuration Wizard. This allows the Configuration Wizard to proceed and rebuild the table which was dropped as well.  

 

 

 