The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Error flushing data System.ServiceModel.FaultException: Exception 'InvalidOperationException' while resolving string IDs: Can't get IDs for strings becaues connection can't be opened

Error flushing data System.ServiceModel.FaultException: Exception 'InvalidOperationException' while resolving string IDs: Can't get IDs for strings becaues connection can't be opened

Created by Michael Almadova, last modified by Kevin.Swinson on Nov 09, 2017

Views: 383 Votes: 1 Revisions: 8

Updated April 29th, 2016

Overview

This article addresses an error in the Orion Web Console that it is unable to communicate with the NTA.BusinessLayer:

ERROR:

SolarWinds.Netflow.Processing.Workflow.NetFlowPacketWorkflowManager - Error flushing data
System.ServiceModel.FaultException: Exception 'InvalidOperationException' while resolving string IDs: Can't get IDs for strings because connection can't be opened.

Environment

  • NTA 4
  • NPM 11

Cause 

This occurs when the NetFlow service is corrupted or is not installed.

Resolution

Repair the NTA service. The Configuration Wizard should automatically launch after the repair. Otherwise, manually launch the Configuration Wizard.