Overview

Configuration Wizard ends with the following error:
Database configuration failed: Error while executing script- Violation of PRIMARY KEY constraint 'PK_NetFlowTransactionLog'. Cannot insert duplicate key in object 'dbo.NetFlowTransactionLog'. The statement has been terminated

Environment

NTA 4.0 and earlier

Resolution

Note: Make sure to backup your database before making any direct changes.

  1. Log in to SQL Management Studio in SQL server using an SQL sa account.
  2. Run the following query against the Orion/SolarWinds database:
    GO
    IF  EXISTS (SELECT * FROM sys.indexes WHERE object_id = OBJECT_ID(N'[dbo].[NetFlowTransactionLog]') AND name = N'PK_NetFlowTransactionLog')
    ALTER TABLE [dbo].[NetFlowTransactionLog] DROP CONSTRAINT [PK_NetFlowTransactionLog]
    GO
  3. Re-run the Configuration Wizard.

 