Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Configuration wizard freezes during the NeflowDatabaseSchema config file process

Configuration wizard freezes during the NeflowDatabaseSchema config file process

Updated June 5, 2017

Overview

The configuration wizard freezes during the NetflowDatabaseSchema.config process after an upgrade to NTA. This can also happen when other modules are upgraded.

Environment

NTA 4.21 or earlier

Upgrading to NTA 4.2 or later

Cause 

During an upgrade to NTA 4.2, a migration occurs due to some changes to the CBQoSStats table which may contain more than ten million rows. Data is copied into a temporary table and it causes the configuration wizard to freeze.

Resolution

Wait for the configuration wizard process to complete or call SolarWinds support for assistance on how to truncate all the CBQoS tables and start to collect data from scratch (all historical data will be lost).

 