The following error is displayed when running the configuration wizard and when the noted NTA stored procedure is not in the database:

Website configuration failed:

Could not find stored procedure 'dbo.upgrade_FlowCorrelationPostDNS_UpgradeNeeded'

Environment

All NTA versions

Cause 

This error is caused when the configuration wizard process failed after an initial installation.

Resolution

  1. Rerun the configuration wizard to recreate the stored procedure.
  2. If this does not work, create a backup of your database and then run the following query via the SQL Management Studio:
CREATE PROCEDURE [dbo].[upgrade_FlowCorrelationPostDNS_UpgradeNeeded]
@instanceID UNIQUEIDENTIFIER
AS
BEGIN
SET NOCOUNT ON; 
SELECT 1 WHERE
EXISTS (SELECT * FROM dbo.sysobjects WHERE id = OBJECT_ID(N'[dbo].[FlowCorrelationPostDNS_Old]') AND OBJECTPROPERTY(id, N'IsUserTable') = 1)
END
GO
 