Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Netflow Traffic Analyzer (NTA) > Can't verify FastBit server version: FastBit Server version '411' doesn't match with expected server version '410' for this client. Please upgrade FastBit server to required version

Can't verify FastBit server version: FastBit Server version '411' doesn't match with expected server version '410' for this client. Please upgrade FastBit server to required version

Updated April 28th, 2016

Overview

You are trying to upgrade NTA version on Orion / NTA application server however you have recieved following error. 

 

NTA Windows Event Error 

Unhandled exception - Disk free space information [Temp - [C:] - 13483536384 bytes free, DB - [C:] - 13483536384 bytes free] : Can't verify FastBit server version: FastBit Server version '411' doesn't match with expected server version '410' for this client. Please upgrade FastBit server to required version.

 

 

Environment

  • NPM 11.5.2 
  • NTA 4.11

Cause 

 The version on the FlowStorage is lower then the version of NTA installed on the application server. 

 

Resolution

 

You must upgrade the NTA FlowStorage DB to the same level of NTA installed on the Primary server and then complete the Configuration Wizard on the Orion sever .

 

Make sure you have restarted the FlowStorage DB Server after the upgrade or have made any other changes . 

 

 