ERROR SolarWinds.Netflow.FastBit.Server.Api.NTAFastBitServerService - Error while executing system command

Created by Malik Haider, last modified by MindTouch on Jun 23, 2016

Views: 1,038 Votes: 0 Revisions: 14

Overview

 

You have received following error when starting NTA service . 

 

The NTA Service restarts with the ASP.Net error message:

 

2015-10-14 09:40:38,752 [73] ERROR SolarWinds.Netflow.FastBit.Server.Api.NTAFastBitServerService - Error while executing system command: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.OutOfMemoryException: Exception of type 'System.OutOfMemoryException' was thrown.

Environment

NTA 4.0.x and later

Cause 

Running the Flow Storage and the Orion database on the same server causes low memory for the Flow Storage Service.

ASP.png

 

Resolution

Migrate Flow Storage and SQL to another dedicated system. For more details, refer to Moving the NTA Flow Storage Database.

 

 

Last modified
20:27, 22 Jun 2016

Tags

Classifications

Public