Submit a ticketCall us

Quickly Address Software Vulnerabilities
Patch Manager is an intuitive patch management software which extends the capabilities of WSUS and SCCM to not only patch Windows® servers and workstations, and Microsoft® applications, but also other 3rd-party applications which are commonly exploited by hackers. Learn more about our patch management solution.

 

Home > Success Center > Log & Event Manager (LEM) > LEM not loading after applying HotFix 2

LEM not loading after applying HotFix 2

Updated January 9, 2017

Overview

This article describes an error which may prevent the LEM Manager from loading after applying a HotFix. 

The following error is displayed in the manager.log file( manager ->watchlog command):

EE:ERR [FileMonitor] {FileMonitor-1:96} EXCEPTION: {}

java.lang.NoClassDefFoundError: com/trigeo/util.file/FileChangedEvent

Environment

LEM 6.3.1 HotFix 2

 

Cause 

The error is caused by not rebooting LEM as needed in the HotFix instructions.

 

Resolution

Reboot LEM

  1. SSH to your LEM appliance and log in to the cmc.
  2. Enter appliance.
  3. Enter reboot.

 

 

 

Last modified
20:30, 29 Mar 2017

Tags

Classifications

Public