The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Log & Event Manager (LEM) > LEM Administrator's Guide > Troubleshoot the LEM reports application

Troubleshoot the LEM reports application

Updated: September 15, 2017

This topic provides information to help you troubleshoot LEM reports.

Troubleshoot the LEM reports application database connection

Use the following table to troubleshoot error messages that may occur with the ping test used to test the connection between the LEM reports application and the data warehouse or the primary data source.

Problem or Error message Description Correction

Manager ping
timed out.

The reports application was unable to connect to the LEM Manager host name or IP address. Confirm the host name (or IP address) you entered is correct.

Confirm that you entered the warehouse host name properly and it matches a valid DNS entry. Try entering the warehouse IP address in the Host Name field.

Sending the authentication packet failed. Could not flush socket buffer.

Reports could resolve and connect to the IP address, but could not authenticate to the database server at that location.

Confirm that the host name (or IP address) is correct and allows connections from the location where you are running the reports application.

This error may also require you to modify the report restrictions.

Server ping test successful, but database connection test failed.

Login incorrect.

Login failed for user [user name].

Reports could resolve, connect to the IP address, and connect to SQL Server, but could not log in using the reports user credentials.

Confirm that the host name (or IP address) you specified contains the SolarWinds database.

The warehouse may require a password for reporting purposes. In this case, click Security and enter the warehouse reporting password.

Logon failed. Database Vendor Code 210 The system running the LEM reports application is not on the list of authorized reporting computers.

To resolve this issue, add the system running the reports application to the list of authorized reporting computers.

To allow specific systems to run the LEM reports application, or to remove all reporting restrictions, see Restrict access to the LEM reports application.

Repair the LEM reports application

If you cannot open the LEM reports application or run reports, complete the following steps.

  1. Uninstall the LEM Reports and Crystal Reports v11 Runtime.

  2. Log in as an administrator and reinstall both components.

  3. On older systems running Windows 7 and Windows Server 2008, adjust the LEM Reports properties to run the program in Windows XP compatibility mode:

    1. Right-click the LEM Reports shortcut on your desktop or in the SolarWinds Log and Event Manager program group in your Windows Start menu and select Properties.

    2. Click the Compatibility tab.

    3. Select Run this program in compatibility mode for, and then select Windows XP (Service Pack 3).

    4. Select Run this program as an administrator.

    5. Click OK.

  4. Launch LEM Reports.

Last modified