Virtualization can give you enormous flexibility with future workloads and can be a key enabler for other areas, like cloud computing and disaster recovery. So, how can you get a handle on the performance challenges in your virtual environment and manage deployments without erasing the potential upside? Learn the four key areas you need to be focusing on to help deliver a healthy and well-performing data center.

Get your free white paper.

Home > Success Center > Log & Event Manager (LEM) > LEM - Knowledgebase Articles > Different detection time in email alert message

Different detection time in email alert message

Updated June 28, 2017

Overview

The LEM email alerts display a different detection time than what is displayed in the DetectionTime and InsertionTime fields of the event as shown in the following example:

Environment

  • LEM 6.3.1
  • VMware

Cause 

There is a time synchronization issue between the guest and VMware host.

Resolution

  1. Verify that the DC and network devices time zones are correctly configured.
  2. Verify that the LEM server and the host are using the correct NTP server and that the guest is configured either to use NTP or the hardware clock is synchronized with the host.
  3. Go to CMC > Appliance > TZconfig if you need to make changes to the guest NTP configuration.
  4. Reboot the appliance to fix the time synchronization issue (CMC > Appliance > Reboot).

 

Last modified

Tags