In this video broadcast, Head Geek™ Tom LaRock is joined by Karen Lopez, Tim Chapman, and David Klee. They’ve known each other for many years, so this discussion was like four friends getting together to talk data and databases. They discussed diagnostic data collection, common performance root causes, reactive tuning versus proactive, and more. Join us for an engaging discussion on these topics! Plus, Tom LaRock will be available to answer your questions live.

Register now.

Home > Success Center > Kiwi Syslog Server > Kiwi Sys - Knowledgebase Articles > Kiwi Web Access install error: The error code is 2738

Kiwi Web Access install error: The error code is 2738

Updated March 11th, 2016

Overview

This article provides brief information and steps to resolve the following Kiwi Web Access installation error:

The installer has encountered an unexpected error installing this package. This may indicate a problem with this package. The error code is 2738.

Environment

  • All Kiwi Syslog Server versions 
  • All Windows versions

Cause 

The installer is attempting to call a VBRuntime property but VBRuntime is not found.

Resolution

  1. Verify the issue by running the Kiwi Web Access installer with logging enabled:
    1. Open an elevated CMD window. 
    2. Go to the following directory:
      • \program files (x86)\syslogd\setup\
    3. Run the following command:
      • kiwisyslogwebaccess_{version}_setup.exe /log c:\kiwiwebinstall.log
      • Note: Replace {version} with latest version available.
    4. Once you receive the error, open c:\kiwiwebinstall.log. The error is similar to  
      • Could not access vbscript runtime for custom action
  2. Fix the issue:
    1. Download and install Visual Basic Runtime 6 SP6 from the following location:
    2. Register vbruntime.dll by running the following command from an elevated CMD window:
      • Windows 32-bit: regsvr32 c:\windows\system32\vbruntime.dll
      • Windows 64-bit: regsvr32 c:\windows\syswow64\\vbruntime.dll
    3. Check the following registry key to ensure that the VBScript.dll is still the default VB Script interpreter:
      • HKCR\CLSID\{B54F3741-5B07-11cf-A4B0-00AA004A55E8}\InprocServer32

Disclaimer: Please note, any content posted herein is provided as a suggestion or recommendation to you for your internal use. This is not part of the SolarWinds software or documentation that you purchased from SolarWinds, and the information set forth herein may come from third parties. Your organization should internally review and assess to what extent, if any, such custom scripts or recommendations will be incorporated into your environment.  You elect to use third party content at your own risk, and you will be solely responsible for the incorporation of the same, if any.

 